Ongoing R&D Effort Will Improve
Marine Boiler Reliability
John R. Brinser and Carl F. Horlitz Jr.*
During the past 15 to 20 years,
the shipbuilding industry has
placed increasing demands upon
the manufacturers of main steam
propulsion machinery to produce
equipment of increasing reliabil-
ity and efficiency. During this
time period, the plant power re-
quirements have steadily in-
creased, machinery space avail-
able has steadily decreased, cycle
conditions have become more ex-
treme, bunkering fuels have been
gradually deteriorating in quality
and, with the emergency of the
energy crunch a few years ago,
a renewed emphasis has been
placed upon high efficiencies.
These requirements have placed
an increasing burden on the al-
ready harsh environment typical
of the firesides and watersides of
marine steam propulsion boilers.
To investigate the phenomena
which affect boiler reliability, the
Maritime Administration in early
1975 funded the first phase of a
program entitled "Improved Ma-
rine Boiler Reliability." The ob-
jective of this initial effort was
to investigate the main problem
areas encountered in the design
and operation of a marine boiler
and, through an investigation of
recent technical papers, ships' op-
erating records, boiler design pa-
rameters, and fuel-oil analyses, to
identify and research certain ba-
sic concepts and parameters and
to explore their effect upon boiler
reliability. This phase was com-
pleted in April 1976.
As a result of the investiga-
tions carried out in the initial
phase, several items relating to
specific areas of marine boiler re-
liability were chosen for labora-
tory-type testing both on board
ship and in land-based facilities.
This second phase also was funded
by the Maritime Administration
and began in July 1976 and will
continue until early 1978. Items
under investigation in this second
phase include high- and low-tem-
perature corrosion rates of vari-
ous superheater and economizer
heat-transfer surfaces, investiga-
tion of superheater steam flow
patterns, and analysis of marine
boiler stack gas.
*Mr. Brinser, project engineer, and
Mr. Horlitz, assistant manager, Com-
bustion Engineering, Inc., C-E Marine
Power Systems, Windsor, Conn., pre-
sented the paper abstracted here be-
fore the recent Annual Meeting of
The Society of Naval Architects and
Marine Engineers. A complete copy
of the paper may be obtained from
the Society, One World Trade Center,
Suite 1369, New York, N.Y. 10048.
Superheater
The primary cause of super-
heater tubing failure is high-
temperature corrosion which is
preceded by the formation of
complex vanadium-based slags on
tubing surfaces.
Consideration of the factors
contributing to high-temperature
slag corrosion of superheaters al-
lows several recommendations to
increase marine boiler superheat-
er reliability. The objective for
ships presently in service is to
minimize the problems within the
boiler operating and design con-
straints, whereas the objective for
future installations could include
design features, material selec-
tions and component configura-
tions which may minimize the
causes of the problem. There is
no single optimum solution to the
high-temperature slag corrosion
problem; however, the first steps
must include the specification of
the superheater tubing environ-
ment and reliability requirements
by the boiler purchaser. The en-
vironment is specified by the qual-
ity of fuel available in the ship's
operating area and the excess air
level, both of which are ship-
owner inputs and superheater con-
figuration and material selections
by the boiler manufacturer to suit
reliability requirements.
Particular attention should be
given to the maintenance of ex-
cess air level in accordance with
the operation and design require-
ments of marine boilers presently
in service. Design and testing
programs in the area of low ex-
cess air combustion equipment
should continue and boiler de-
signs should incorporate this
equipment.
Superheater tubing material se-
lection should be determined by
the environment and reliability
requirements of the purchaser.
Although the use of more exotic
materials enhances superheater
reliability, their use may not be
cost effective due to significant
higher initial costs and generally
longer material and fabrication
lead times.
Superheater reliability also can
be improved through configuration
modifications or "over design."
Configuration modifications in-
clude the installation of additional
screen rows and the selection of
multistage superheaters. The first
alternative reduces the radiant
heat input to the superheater and
results in minor reductions of
maximum tube metal tempera-
tures ; selection of this alternative
might be warranted if the use of
very poor quality fuels is antici-
pated and if the boiler envelope
will tolerate the coincident in-
crease in superheater size. The
orientation of the superheater
elements themselves has a sig-
nificant effect on superheater re-
liability. Vertically oriented su-
perheaters have been proven to
be less susceptible to slagging
and therefore are affected to a
lesser degree by high-temperature
corrosion than a horizontally con-
figured arrangement. Superheater
slagging also is directly affected
by soot blower orientation, and in
this regard it is important to have
soot blower lance configured in a
perpendicular fashion to the axis
of the superheater elements.
The utilization of fuel-oil addi-
tives is the one remaining choice
to be considered for superheater
reliability improvement. Although
the use of fuel-oil additives has
been shown to be effective in re-
ducing the formation of highly
corrosive slags and, hence, in re-
ducing high-temperature corro-
sion, an important consideration
prior to their widespread accept-
ance and application is that of
fireside cleanliness. Experience
has shown that the use of fuel-
oil additives greatly increases the
solids burden of the flue gases.
It is recommended that sufficient
sootblowing capacity be proved
through testing prior to the en-
dorsement of the fuel-oil additive
technique to reduce high-temper-
ature corrosion. Additionally, it
is recommended that chemical
additives be tested to determine
which ones of those presently
available and advertised commer-
cially are the most beneficial.
Superheater material corrosion
rates are presently being deter-
mined through the exposure of
two multimaterial controlled-tem-
perature corrosion probes located
in the port boiler of the Stonewall
Jackson, a Waterman Steamship
Company LASH vessel. The high-
temperature corrosion probes will
be removed for analysis at six-
month intervals.
At the present time, the au-
thors' company is designing and
constructing a superheater air-
flow model. The model will be
tested to provide quantitative data
on superheater steam-side flow
distribution for various modeled
steaming loads and superheater
configurations. The major vari-
ables include location of the sat-
urated-steam inlet, superheater
pass size, desuperheater location
and model flow rates.
During model flow tests, super-
heater element flow distribution
will be monitored by pressure
transducers and continuously re-
corded. Results of the testing
program will be used to formu-
late a computer-based mathemat-
ical flow model whose validity will
be checked by flow model testing.
After the satisfactory mathemat-
ical flow model has been devel-
oped, existing heat-transfer and
tube-material temperature calcu-
lation programs will be used to
establish correlations among tube
metal temperatures, superheater
flow distribution and boiler load-
ings for allowable superheater
tubing materials.
Stack Gas Testing
In order to define more clearly
a typical corrosion environment
for cold-end heat exchangers, a
program of stack-gas analysis
was undertaken on an operating
LASH vessel. The major thrust
of this investigation was to ob-
tain sufficient information to per-
mit the calculation of sulfuric-
acid dewpoints at various boiler
loadings and excess-air levels. In
order to accomplish this, tests
for sulfur dioxide, sulfur trioxide,
oxygen, and water-vapor concen-
tration in the stack gas were con-
ducted over a wide range of boiler
loadings and excess-air levels. The
boiler used for the test was a
Combustion Engineering V2M8
welded-wall boiler equipped with
two downward-firing steam-atom-
izing marine oil burners, a steam
air heater, and an economizer.
Over the course of five days,
extensive testing and shipboard
analyses were conducted at a va-
riety of boiler loads and excess air
levels, including a series of tests
during minimum load conditions
in port. Two representatives from
Combustion Engineering's Field
Testing and Performance Results
Group performed the highly spe-
cialized gas analysis tests. A third
technical representative coordi-
nated the test program with the
ship's engineering staff and main-
tained boiler performance records.
While the dewpoint tempera-
ture of sulfuric acid vapor may
be an important parameter in de-
termining the temperature below
which condensation of acid is ex-
pected to occur, the most signifi-
cant factor determining the serv-
ice life of heat-recovery equip-
ment is the rate of corrosion of
the heat-exchanger surface.
There are, however, no accepted
methods for predicting by calcu-
(continued on page 18)
November 15, 1977 17
Digital Wave Publishing